Before use of the Flex-coil® Swivel Sets, Shoe Mounting Kits must be
installed in selected cages. If you have not already mounted the Shoe and
tubing tabs/clips please click on the link below.
To prepare the cage to give fluids follow the following steps. |
||||||||||||||||||||||
| Flex-coil® Swivel Set-up Instructions .pdf - 2 pages | ||||||||||||||||||||||
|
Select the appropriate Flex-coil® Swivel Set: Three (3) foot coils (CR9003) are ideal for cat-sized cages; five (5) foot coils (CR9005) for average sized dog cages; and, ten (10) foot coils (CR9010) for runs and insert it in the Shoe. Remove the protective cap from the female Luer connector on the swivel device and attach the male Luer end connector of an I.V. set. Insert the Flex-coil® Swivel Set in the Shoe mounted at the top center of the cage. To remove a Flex-coil® Swivel squeeze the sides of the swivel and slide it forward out of the Shoe.
|
![]() |
|||||||||||||||||||||
|
Place the primary I.V. set tubing
inside the cage into the gray tubing
tab/clips to hold it against the top of
the cage.
|
||||||||||||||||||||||
![]() |
||||||||||||||||||||||
|
Prime the primary I.V. set and Flex-coil® Swivel Set by partially filling
the drip chamber and temporarily
opening the flow control
device on the I.V. set or
starting the infusion pump.
|
||||||||||||||||||||||
![]() |
||||||||||||||||||||||
| Preparing the patient to receive I.V. fluids with the Flex-coil® Swivel System: | ||||||||||||||||||||||
|
Insert an I.V. catheter in a cephalic, jugular or saphenous vein and secure it in place.
|
![]() |
|||||||||||||||||||||
|
Prime the appropriate sized Extension Set and close the on/off clamp. The 14 inch Extension Set with KINK-SAFE Adapter (EXT14) is ideal for cats, small dogs and puppies; the 24 inch Extension Set with KINKSAFE Adapter (EXT24) is ideal for average sized dogs; and, the 36 inch Extension Set with KINK-SAFE Adapter (EXT36) is ideal for giant breed dogs. Attach the male Luer connector of the KINK-SAFE adapter to the hub of the I.V. catheter. With a syringe attached to the female Luer connector on the Extension Set flush several milliliters of fluid through the Extension Set and I.V. catheter to check the patency of the vein. |
![]() |
|||||||||||||||||||||
|
Attach the male Luer connector on the end of the coil to the female Luer connector at the proximal end of the Extension Set. Depress the tab on the releasable cable tie at the end of the coil, open the tie, pass it around a collar, releasable collar, identification band or harness and secure the cable tie so that end of the coil is positioned behind the head between the shoulder blades (out of sight and out of easy reach). |
![]() |
|||||||||||||||||||||
|
The final steps are to open the on/off
clamp on the Extension Set and set the
rate of fluid flow on the infusion pump
or with the flow control device on the
primary I.V. set.
|
![]() |
|||||||||||||||||||||
|
|
||||||||||||||||||||||
|
|
||||||||||||||||||||||
|